# CURB-65 vs PSI vs SMART-COP (Pneumonia Severity Comparison)

Compare three pneumonia severity scores side-by-side from one set of inputs to support concordance reading. CURB-65 (0-5: Confusion, Urea, RR, BP, age ≥65) — quick bedside triage; PSI/PORT (Fine 1997, 5 risk classes) — the most accurate mortality stratification, more complex; SMART-COP (0-10, 2 points each for SBP <90 and hypoxia, 1 point each for multilobar CXR, albumin <3.5, RR ≥25, tachycardia ≥125, confusion, pH <7.35) — predicts need for ICU respiratory/vasopressor support. Each score has a different focus: CURB-65 is fast; PSI is more precise; SMART-COP identifies who needs ICU. The tool reports each score's total/category/interpretation and an agreement analysis (whether all three point to outpatient/admission/ICU). When scores disagree, favor the more conservative disposition. Derived from Lim 2003, Fine 1997, Charles 2008. Not medical advice.

> Canonical page: https://test.elysiatools.com/en/tools/curb-65-vs-pneumonia-severity

- **Category:** Health

- **Keywords:** CURB-65, PSI, PORT, SMART-COP, pneumonia, CAP, severity, comparison, ICU, triage, concordance

## Overview

Compare CURB-65, PSI/PORT, and SMART-COP pneumonia severity scores from one set of clinical inputs. The tool returns each total, category, interpretation, and an agreement analysis for outpatient care, hospital admission, or ICU-level concern. It is for clinical reference and is not medical advice.

## Inputs

- **Age** (number): Age in years. Used by all three scores.
- **Sex** (select): PSI subtracts 10 points for women.
- **Nursing home resident** (checkbox): PSI +10.
- **Confusion (new onset)** (checkbox): CURB-65 +1; SMART-COP +1.
- **Urea > 7 mmol/L (BUN > 20 mg/dL)** (checkbox): CURB-65 +1; PSI +20 (BUN ≥30 mg/dL family).
- **Respiratory rate ≥ 30/min** (checkbox): CURB-65 +1; PSI +20.
- **Respiratory rate ≥ 25/min (SMART-COP)** (checkbox): SMART-COP +1 (lower RR threshold than CURB-65).
- **Systolic BP < 90 mmHg** (checkbox): CURB-65 +1; PSI +20; SMART-COP +2.
- **Diastolic BP ≤ 60 mmHg** (checkbox): CURB-65 +1 (CURB-65 BP criterion, OR with SBP).
- **Pulse ≥ 125/min** (checkbox): PSI +10; SMART-COP +1.
- **Temperature < 35°C or ≥ 40°C** (checkbox): PSI +15 (and PSI Step 1 screening).
- **Arterial pH < 7.35** (checkbox): PSI +30; SMART-COP +1.
- **Sodium < 130 mmol/L** (checkbox): PSI +20.
- **Glucose ≥ 250 mg/dL** (checkbox): PSI +10.
- **Hematocrit < 30%** (checkbox): PSI +10.
- **PaO₂ < 60 mmHg or O₂ sat < 90%** (checkbox): PSI +10; SMART-COP +2 (hypoxia).
- **Pleural effusion on chest X-ray** (checkbox): PSI +10.
- **Multilobar infiltrate on chest X-ray** (checkbox): SMART-COP +1.
- **Albumin < 3.5 g/dL** (checkbox): SMART-COP +1.
- **Neoplastic disease** (checkbox): PSI +30 (and PSI Step 1 screening).
- **Liver disease** (checkbox): PSI +20 (and PSI Step 1 screening).
- **Congestive heart failure** (checkbox): PSI +10 (and PSI Step 1 screening).
- **Cerebrovascular disease** (checkbox): PSI +10 (and PSI Step 1 screening).
- **Renal disease** (checkbox): PSI +10 (and PSI Step 1 screening).

## When to use

- When assessing community-acquired pneumonia severity with several validated scoring systems.
- When you need to compare rapid CURB-65 triage with the more detailed PSI and ICU-focused SMART-COP score.
- When the scores may disagree and you want a side-by-side view to support a more conservative disposition decision.

## How it works

- Enter the patient's age and sex, then select applicable clinical findings, vital-sign thresholds, laboratory results, imaging findings, and comorbidities.
- The tool calculates CURB-65, PSI/PORT, and SMART-COP from the same inputs.
- Each result includes a total score, risk category, and interpretation.
- The tool compares the three outputs and reports whether they are concordant for outpatient care, admission, or ICU-level concern.

## Use cases

- Emergency and acute-care triage for adults with suspected community-acquired pneumonia.
- Clinical education comparing the inputs and focus of CURB-65, PSI, and SMART-COP.
- Structured review of discordant pneumonia severity assessments before disposition planning.

## Frequently asked questions

### What scores does this tool compare?

It compares CURB-65, PSI/PORT, and SMART-COP for pneumonia severity.

### What information is required?

Age and sex are required. Other inputs cover symptoms, vital signs, laboratory findings, chest X-ray findings, and selected comorbidities.

### What does CURB-65 measure?

CURB-65 uses confusion, urea, respiratory rate, blood pressure, and age 65 or older for rapid bedside triage.

### What is SMART-COP designed to identify?

SMART-COP helps identify patients who may need ICU respiratory or vasopressor support.

### What should I do if the scores disagree?

Review the individual results and favor the more conservative disposition, with clinical judgment and local guidance.

## Related tools

- [Blood Gas Acid-Base Interpretation (AG / ΔAG)](https://test.elysiatools.com/en/tools/blood-gas-anion-gap): Complete ABG analysis: pH, primary disorder, compensation (Winter's formula), anion gap ± albumin correction, delta ratio for mixed disorder detection. Derived from Emmett 2016, Kraut 2007, Rastegar 2007, LITFL, MDCalc, and Adrogué 1998. Not medical advice.
- [Formula / Chart Heavy PDF Analyzer](https://test.elysiatools.com/en/tools/formula-chart-heavy-pdf-analyzer): Compare local and hybrid OpenDataLoader extraction to identify PDF pages where formulas, charts, or dense visuals may need AI-assisted parsing
- [Image Color Extractor](https://test.elysiatools.com/en/tools/image-color-extractor): Extract dominant colors from images using various algorithms including k-means clustering and histogram analysis
- [BCA Assay Calculator (Protein Standard Curve)](https://test.elysiatools.com/en/tools/bca-assay-calculator): Least-squares A562 curve fit, back-calculated unknowns with dilution factor, extrapolation flags, and detergent/reducing-agent compatibility notes. Educational use only.
- [Bradford Assay Calculator (BSA Standard Curve)](https://test.elysiatools.com/en/tools/bradford-assay-calculator): Least-squares BSA curve, back-calculated unknowns with dilution factor, extrapolation flags, and protein-specific dye-response caveats. Educational use only.
- [DNA Concentration Calculator (A260 Absorbance)](https://test.elysiatools.com/en/tools/dna-concentration-a260): Beer–Lambert DNA quantitation: c = A260 × dilution factor × K / path length with 1 OD = 50 µg/mL dsDNA or 33 µg/mL ssDNA, plus ng/µL, total yield, and a 0.1–1.5 linear-range check. Derived from Marmur & Doty, Sambrook & Russell, Thermo Fisher NanoDrop notes. Educational use only.
- [Image Metadata Extractor](https://test.elysiatools.com/en/tools/image-metadata): Extract comprehensive metadata from images including EXIF, IPTC, XMP, and technical information
- [OD260/230 Nucleic Acid Purity Ratio Calculator](https://test.elysiatools.com/en/tools/od260-230-ratio): Check salt/organic-solvent contamination with A260/A230 (pure 2.0–2.2; below 2.0 = guanidinium/phenol/EDTA/salt carryover from TRIzol or columns), with an optional A260/280 cross-check. Derived from Thermo Fisher T042, Sambrook & Russell, Manchester 1995. Educational use only.

## Samples

- [Web Image Processing Python Samples](https://test.elysiatools.com/en/samples/web-image-processing-python): Web Python image processing examples using PIL/Pillow including reading, saving, resizing, and format conversion
- [Android Image Processing Java Samples](https://test.elysiatools.com/en/samples/android-image-processing-java): Android Java image processing examples including reading/saving images, scaling, and format conversion
- [Android Image Processing Kotlin Samples](https://test.elysiatools.com/en/samples/android-image-processing-kotlin): Android Kotlin image processing examples including reading/saving images, scaling, and format conversion
- [Ethereum Smart Contracts with Solidity](https://test.elysiatools.com/en/samples/ethereum-solidity): Comprehensive Ethereum smart contract development examples including ERC-20, ERC-721, DeFi protocols, and hardware wallet integration
