Set the material budget with stoichiometry, earn the reaction orders from initial-rate data, confirm them against the integrated concentration-time fit with its rate constant and half-life, then carry the constant to any temperature by the Arrhenius ratio.
New to this workflow? Follow the steps in order, starting with the first tool below. Already know what you need? Jump straight to the matching step — every tool in this workflow is listed in the comparison table.
Kinetics analysis begins with accounting, not calculus. The balanced equation and the reactant masses name the limiting reagent, the theoretical yield, and — once the run is done — the percent yield as actual over theoretical. This budget does two jobs for the rate work ahead. It sets the ceiling the concentration curve is falling toward, and it catches the classic embarrassment early — a concentration that stops decaying at half conversion was not measuring your reaction but a side process or an equilibrium. The rate law describes a reaction that actually runs; the budget is how you know it ran.
Orders are earned from data
The rate law's exponents are not chosen — they are extracted. The initial-rate method runs a series of experiments, one per line, each with its concentrations and its measured early rate. For a single reactant, log-log least squares across the series returns the order; for two, the method of pairs at fixed concentration separates their contributions. The tool flags orders within 0.05 of an integer, and the flag deserves respect rather than obedience — fitted value and flag travel together, the integer is adopted when the whole data set tells one story, and the deviation stays on record. An order asserted from plausibility is an assumption wearing decimal places; an order extracted from a table is evidence.
The curve confirms the law
One experiment, watched whole, can confirm what the first moments proposed. The integrated rate equations — zero, first, second order — each predict a different shape for concentration against time, and fitting all three lets the data pick the winner. The prize is more than the order — the rate constant arrives with its unit, which itself encodes the order, the half-life arrives consistent with both, and the goodness-of-fit arrives as the honesty check. A first-order fit with the half-life equal to the natural log of two over k has passed a real internal test. And when this order agrees with the initial-rate order, the rate law graduates from plausible to defensible.
The constant travels with temperature
A rate constant is married to its temperature, and the Arrhenius ratio is the passport between them. Given one reference constant and an activation energy, the ratio form cancels the pre-exponential factor entirely — the estimate needs no absolute Arrhenius parameters, only a faithful k, its temperature, and an Ea accepted in kilojoules, kilocalories, or joules per mole. The result inherits the reference unit and the reference error, which sets the discipline — anchor near the working temperature, treat long extrapolations as hypotheses, and say so in the report. A k carried honestly to five degrees is worth more than one launched hopefully across fifty.
Where this workflow stops
This page extracts rate laws from measured data — budget, orders, constant, half-life, temperature behavior. Around it, the neighbors hold their ground. Balancing the equation in the first place, preparing the solutions, and the periodic-table reference bench belong to the chemistry-lab calculations. Producing the concentration-time series itself — measuring concentrations by absorbance with Beer-Lambert arithmetic — belongs to the absorbance quantification workflow, which is where spectrophotometer readings become the molarities this page consumes. And when the exponential growth is living cells rather than decaying reagents, the doubling-time discipline belongs to the cell-culture counting pages. Earn the rate law here — then let the neighbors feed the next experiment.
A balanced equation for the reaction — balancing belongs to the chemistry-lab bench, and kinetics analysis starts from its result.
An initial-rate table with one experiment per line, or a concentration-time series for the reactant being tracked.
For temperature work, one reference rate constant at a known temperature plus an activation energy.
Reactant masses for the material budget, so the limiting reagent and the expected yield are known before any rate is fitted.
Turn rate measurements into a rate law you can defend
1
Initial rates or integrated fit?
Initial-rate experiments give the orders directly from a few early measurements; the integrated fit extracts order, constant, and half-life from one full time series — running both makes the order defensible, because agreement between independent evidence is the proof.
The orders from initial rates and from the integrated fit agree, or the disagreement is explained before the rate law is used anywhere.
The reported rate constant carries its unit — which encodes the order — alongside the goodness-of-fit of the equation it came from.
The half-life is consistent with the constant and the order, checked for first order as the natural log of two over k.
The Arrhenius estimate states the reference constant, its temperature, and the activation energy with its unit, and the result inherits the reference unit.
The limiting reagent is named and the percent yield is recorded as actual over theoretical, so the fitted curve is known to describe the reaction and not a side process.
Images, Audio & Video657
Image, audio, and video processing, conversion, and optimization tools
Math, Date & Finance647
Calculators, numerics, date logic, statistics, and finance tools
Design & Color298
Color, layout, graphics, visual styling, and design helper tools
Text & Writing209
Writing, cleanup, formatting, extraction, and text analysis tools
Developer & Web193
Developer utilities, networking, web debugging, and automation helpers
Conversion & Encoding175
Format, file, archive, unit, and encoding conversion tools
Initial-rate method: single-reactant log-log fit or two-reactant method of pairs, with k back-calculated per experiment.
Science & Education
Fit zero-order, first-order, and second-order rate equations to concentration-time data. Get reaction order, rate constant k, half-life t½, and R² goodness-of-fit.
k(T) from a reference point and Ea via the Arrhenius ratio, with kJ/kcal/J activation energy conversion built in.
Science & Education
Set the material budget first
From the balanced equation and the reactant masses, name the limiting reagent, the theoretical yield, and the percent yield — the conversion the rate law will be chasing, and the check that a decaying concentration is the reaction and not an impurity.
2
Earn the orders from initial rates
3
Confirm the law against the whole curve
4
Carry the constant to any temperature
Snap near-integer orders or keep the fitted value?
Orders within 0.05 of an integer are flagged as such — report the fitted value together with the flag, adopt the integer only when the whole data set supports it, and keep the deviation on record.
Which reference point for the Arrhenius estimate?
The estimated constant inherits both the unit and the error of the reference — anchor it near the working temperature with a well-fitted k, and treat far extrapolations as hypotheses rather than predictions.
Feed the one-experiment-per-line table — concentrations and initial rate — to get orders by log-log least squares for a single reactant or the method of pairs at fixed concentration for two, with near-integers flagged.
Fit the zero-, first-, and second-order integrated equations to the concentration-time series and take the winner — order, rate constant, half-life, and goodness-of-fit together, with the unit of k announcing the order it implies.
Estimate the rate constant at a target temperature from the reference constant and the activation energy using the Arrhenius ratio, which cancels the pre-exponential factor and hands the result the reference unit.
Math & Numbers
Reaction Stoichiometry Calculator
Determine the limiting reagent and compute theoretical yield, actual yield, and percent yield from a balanced reaction.