This tool is for informational purposes only and does not constitute medical, financial, or legal advice; consult a qualified professional for advice.

Compute CO = VO₂ / (CaO₂ − CvO₂) / 10 (L/min) with the Fick principle. Requires PA-catheter mixed venous samples. VO₂ defaults to 250 mL/min. Derived from Fick 1870, StatPearls, LITFL, West, Leach 2002. Not medical advice.

Execution

Run this tool

Fill in the form, run the tool, and review the result in one place.

Samples

Examples that match this tool

Related

Continue with connected tools and hubs

Written by the Elysia Tools team

Tool usage guide

Learn when to use this tool, what it supports, and how real users apply it.

Key facts

Category
Health
Input types
number
Output type
json
Sample coverage
4
API ready
Yes

Overview

The Cardiac Output by Fick Principle calculator estimates cardiac output in L/min from hemoglobin, arterial and mixed venous oxygen measurements, and oxygen consumption. It uses the Fick equation and requires mixed venous samples obtained through a pulmonary artery catheter. This tool is not medical advice.

When to use

  • Estimate cardiac output when arterial and pulmonary-artery mixed venous oxygen data are available.
  • Review the arterial–venous oxygen difference alongside the calculated Fick cardiac output.
  • Use a measured VO₂ value when available, or use the default estimate of 250 mL/min for a resting adult.

How it works

  1. 1Enter hemoglobin, SaO₂, PaO₂, SvO₂, and PvO₂ values using the specified units and fractional saturation format.
  2. 2The calculator derives arterial oxygen content with CaO₂ = 1.34 × Hb × SaO₂ + 0.003 × PaO₂.
  3. 3It derives mixed venous oxygen content with CvO₂ = 1.34 × Hb × SvO₂ + 0.003 × PvO₂.
  4. 4It calculates cardiac output as CO = VO₂ ÷ (CaO₂ − CvO₂) ÷ 10 and rounds the result to the selected decimal places.

Use cases

  • A critical care clinician can estimate cardiac output from pulmonary artery catheter data and arterial blood gas measurements.
  • A cardiology trainee can check each component of the Fick calculation, including CaO₂, CvO₂, and the oxygen difference.
  • A hemodynamics review can compare a resting estimate with a calculation using directly measured oxygen consumption.

Examples

1. Normal resting cardiac output

Cardiology trainee

Background

A resting adult has hemoglobin of 15 g/dL, arterial saturation of 0.97, arterial PO₂ of 100 mmHg, mixed venous saturation of 0.75, and mixed venous PO₂ of 40 mmHg.

Problem

Calculate cardiac output and review the oxygen content difference.

How to use

Enter the five measurements and leave VO₂ at its default of 250 mL/min.

Hemoglobin: 15 g/dL; SaO₂: 0.97; PaO₂: 100 mmHg; SvO₂: 0.75; PvO₂: 40 mmHg; VO₂: 250 mL/min; decimal places: 2.

Outcome

CaO₂ is 19.80 mL O₂/dL, CvO₂ is 15.20 mL O₂/dL, and the arterial–venous difference is 4.60 mL O₂/dL. Calculated cardiac output is approximately 5.43 L/min.

2. Low-output cardiogenic shock example

Critical care clinician

Background

A patient has hemoglobin of 12 g/dL, arterial saturation of 0.92, arterial PO₂ of 60 mmHg, mixed venous saturation of 0.50, and mixed venous PO₂ of 30 mmHg.

Problem

Estimate cardiac output using the available oxygen measurements.

How to use

Enter the arterial and mixed venous values, then use VO₂ of 250 mL/min or replace it with a measured value if available.

FAQ

What inputs are required?

Hemoglobin, SaO₂, PaO₂, SvO₂, and PvO₂ are required. VO₂ is optional.

What does the default VO₂ value mean?

VO₂ defaults to 250 mL/min, an estimate for a 70 kg adult at rest.

Can I enter a measured VO₂?

Yes. Enter the measured whole-body oxygen consumption in mL/min to replace the default estimate.

What type of venous sample is needed?

SvO₂ and PvO₂ should come from mixed venous blood obtained through a pulmonary artery catheter, not a peripheral venous sample.

What does the result include?

The JSON result includes cardiac output, arterial and venous oxygen content, the arterial–venous oxygen difference, and the VO₂ source.

Hub

Critical Care Blood Gas, Oxygenation, and Hemodynamics Workflow

Connect ABG acid-base interpretation with oxygenation, cardiac output, and vascular resistance calculations for structured clinical checking.

Home
Tools3212
Samples593
Visualizations471
Viewers103
Hubs239
Tags333
Images, Audio & Video657

Image, audio, and video processing, conversion, and optimization tools

Math, Date & Finance647

Calculators, numerics, date logic, statistics, and finance tools

Design & Color298

Color, layout, graphics, visual styling, and design helper tools

Text & Writing209

Writing, cleanup, formatting, extraction, and text analysis tools

Developer & Web193

Developer utilities, networking, web debugging, and automation helpers

Conversion & Encoding175

Format, file, archive, unit, and encoding conversion tools

Lead Generation Quiz Launch and Contact Handoff
Memorial Drafts: Family Review and Print Handoff
Private Habit Records: Backup, Restore and Sharing Review
Article to X and LinkedIn Drafts: Fact Review and Handoff
Markdown Interactive Deck Review and Offline Handoff

© 2026 Elysia Tools. All rights reserved.

DocsPricingAboutTerms of ServicePrivacy PolicyCookiesContact
Python

Web Image Processing Python Samples

Web Python image processing examples using PIL/Pillow including reading, saving, resizing, and format conversion

Java

Android Image Processing Java Samples

Android Java image processing examples including reading/saving images, scaling, and format conversion

Kotlin

Android Image Processing Kotlin Samples

Android Kotlin image processing examples including reading/saving images, scaling, and format conversion

Rust

Web Image Processing Rust Samples

Web Rust image processing examples including image read/save, scaling, and format conversion

Health

A-a Gradient (Alveolar-Arterial O₂)

Calculate the alveolar-arterial O₂ gradient to distinguish hypoxemia causes. PAO₂ = FiO₂×(P_atm−47) − PaCO₂/0.8; A-a = PAO₂ − PaO₂. Normal ≈ (Age+10)/4. Elevated → V/Q mismatch, shunt, diffusion impairment. Derived from StatPearls, LITFL, Cornell PICU, and Martin 1999. Not medical advice.

Health

Alveolar Gas Equation (PAO₂ Calculator)

Calculate PAO₂ = FiO₂ × (P_atm − 47) − PaCO₂ / RQ. Defaults: P_atm 760 mmHg (sea level), RQ 0.8. Gives a directional hint vs expected ~100 mmHg. For full A-a gradient interpretation use a-a-gradient-calculator. Derived from StatPearls, LITFL, Cornell PICU, and West. Not medical advice.

Health

Alveolar Ventilation Calculator (VA)

Calculate VA = (VT − VD) × RR in L/min. VD may be supplied or estimated as ~2 mL/kg body weight. Normal resting ~4–6 L/min; low → hypercapnia, high → hypocapnia. Derived from West, LITFL, StatPearls, and Radford 1955. Not medical advice.

Health

Apgar Score (Newborn 1 & 5 min)

Calculate the Apgar score to assess newborn condition at 1 minute and 5 minutes after birth. Five signs are each scored 0–2 at both time points: Appearance (skin color), Pulse (heart rate), Grimace (reflex irritability), Activity (muscle tone), and Respiration. Each time point totals 0–10. Interpretation: 7–10 reassuring; 4–6 moderately abnormal (may need assistance); 0–3 critically low (immediate resuscitation). The tool reports both the 1-min and 5-min scores, the change (delta), and per-time-point interpretation. A 5-min score, and especially the change from 1 to 5 min, indicates response to resuscitation; persistent low 5-min scores warrant continued resuscitation and reassessment at 10 min. Derived from Apgar 1953, reaffirmed by ACOG/AAP. The Apgar is a physiologic snapshot at a moment in time and is not, by itself, a marker of asphyxia or long-term neurologic outcome. Not medical advice.

Hemoglobin: 12 g/dL; SaO₂: 0.92; PaO₂: 60 mmHg; SvO₂: 0.50; PvO₂: 30 mmHg; VO₂: 250 mL/min; decimal places: 2.

Outcome

CaO₂ is 14.97 mL O₂/dL, CvO₂ is 8.13 mL O₂/dL, and the arterial–venous difference is 6.84 mL O₂/dL. Calculated cardiac output is approximately 3.65 L/min, categorized by the example result as low.