Elysia Tools

Browse tools, examples, visual explainers, and topic guides from one clear workspace.

Top Categories

Hubs

Language
ZHDERUPTENFRES

Elysia Tools

Navigation

Math & Numbers

Fatigue Limit Calculator (Goodman / Gerber / Soderberg)

· Last updated:2026-07-26

Mean-stress fatigue correction under cyclic loading. Given stress amplitude σ_a, mean stress σ_m, and material σ_uts / σ_-1 (endurance limit) / σ_y, compute safety factors from three classical criteria: Modified Goodman (linear, conservative), Gerber (parabolic, better for ductile metals), and Soderberg (uses σ_y, most conservative). Reports the governing (smallest) value and whether the operating point lies inside the Goodman line.

Execution

Run this tool

Fill in the form, run the tool, and review the result in one place.

Samples

Examples that match this tool

Related

Continue with connected tools and hubs

Written by the Elysia Tools team
Math502
Mechanical Design4

Tool usage guide

Learn when to use this tool, what it supports, and how real users apply it.

Key facts

Category
Math & Numbers
Input types
number
Output type
json
Sample coverage
4
API ready
Yes

Overview

The Fatigue Limit Calculator estimates fatigue safety factors under cyclic loading using the Modified Goodman, Gerber, and Soderberg criteria. Enter stress amplitude, mean stress, and the applicable material strengths to compare criteria, identify the governing minimum safety factor, and check the operating point against the Goodman line.

When to use

  • Evaluate fatigue safety under cyclic loading with a known stress amplitude and mean stress.
  • Compare Goodman, Gerber, and Soderberg mean-stress correction criteria during mechanical design.
  • Check whether an operating point falls inside the Goodman line and identify the most conservative criterion.

How it works

  1. 1Enter the alternating stress amplitude σ_a in MPa; this value must be greater than zero.
  2. 2Enter the mean stress σ_m and the material properties required for the selected calculations: ultimate strength σ_uts, endurance limit σ_-1, and yield strength σ_y.
  3. 3The calculator computes Goodman, Gerber, and Soderberg safety factors when their required inputs are available.
  4. 4The result reports the smallest, governing safety factor and whether the point is inside or outside the Goodman line.

Use cases

  • Preliminary fatigue checks for shafts, brackets, fasteners, and other cyclically loaded components.
  • Comparison of conservative and less conservative mean-stress correction methods for material selection and design review.
  • Screening operating points before detailed fatigue testing or a broader mechanical design analysis.

Examples

1. Compare three fatigue criteria for a steel component

Mechanical design engineer

Background

A component experiences a 100 MPa stress amplitude and a 200 MPa tensile mean stress. Its material data are available for all three criteria.

Problem

Determine the safety factor from each criterion and identify the governing result.

How to use

Enter σ_a = 100 MPa, σ_m = 200 MPa, σ_uts = 800 MPa, σ_-1 = 300 MPa, and σ_y = 500 MPa.

Decimal places: 4

Outcome

Goodman n = 1.7143, Gerber n = 2.8125, and Soderberg n = 1.3636. Soderberg governs, and the point is inside the Goodman line.

2. Screen a high mean-stress fatigue condition

疲劳分析工程师

Background

A cyclic load produces a 150 MPa stress amplitude and a 300 MPa tensile mean stress in a material with σ_uts = 600 MPa, σ_-1 = 250 MPa, and σ_y = 400 MPa.

Problem

Check whether the operating point satisfies the Goodman criterion and find the most restrictive safety factor.

How to use

Enter σ_a = 150 MPa, σ_m = 300 MPa, σ_uts = 600 MPa, σ_-1 = 250 MPa, and σ_y = 400 MPa.

FAQ

What does the stress amplitude represent?

Stress amplitude is σ_a = (σ_max − σ_min) / 2, expressed in MPa. It must be greater than zero.

What does mean stress represent?

Mean stress is σ_m = (σ_max + σ_min) / 2. Tensile mean stress generally reduces fatigue safety.

Which material inputs are needed?

Goodman and Gerber require ultimate strength σ_uts and endurance limit σ_-1. Soderberg also requires yield strength σ_y.

What is the governing safety factor?

It is the smallest safety factor among the available Goodman, Gerber, and Soderberg results.

What does a safety factor below 1 mean?

A value below 1 indicates that the calculated operating condition does not meet that criterion.

Home
Tools3212
Samples593
Visualizations471
Viewers103
Hubs239
Tags333
Images, Audio & Video657

Image, audio, and video processing, conversion, and optimization tools

Math, Date & Finance647

Calculators, numerics, date logic, statistics, and finance tools

Design & Color298

Color, layout, graphics, visual styling, and design helper tools

Text & Writing209

Writing, cleanup, formatting, extraction, and text analysis tools

Developer & Web193

Developer utilities, networking, web debugging, and automation helpers

Conversion & Encoding175

Format, file, archive, unit, and encoding conversion tools

Lead Generation Quiz Launch and Contact Handoff
Memorial Drafts: Family Review and Print Handoff
Private Habit Records: Backup, Restore and Sharing Review
Article to X and LinkedIn Drafts: Fact Review and Handoff
Markdown Interactive Deck Review and Offline Handoff

© 2026 Elysia Tools. All rights reserved.

DocsPricingAboutTerms of ServicePrivacy PolicyCookiesContact
Media

Copyright-Free MP3 Audio Samples

Collection of royalty-free audio samples for testing and development purposes including nature sounds, meditation music, and ambient audio

Python

Web Image Processing Python Samples

Web Python image processing examples using PIL/Pillow including reading, saving, resizing, and format conversion

Media

SVG Samples

Scalable Vector Graphics (SVG) samples demonstrating various SVG features and techniques

Java

Android Image Processing Java Samples

Android Java image processing examples including reading/saving images, scaling, and format conversion

Math & Numbers

Angular Velocity Converter (rad/s / rpm / deg/s / Hz)

Convert angular velocity (angular speed) between radian per second (rad/s, SI base), revolutions per minute (rpm = 2π/60 rad/s), degrees per second (deg/s = π/180 rad/s), and hertz (Hz, used as revolution per second = 2π rad/s). Converts via rad/s to the target unit and lists all four equivalents. Note: 1 Hz in angular-frequency context means one full revolution per second, so 1 Hz = 2π rad/s ≈ 6.283185307 rad/s. Reference: vinyl LP 33⅓ rpm ≈ 3.49 rad/s, car engine idle ~800 rpm ≈ 83.8 rad/s.

Health

Free Water Clearance Calculator

Calculate solute-free water clearance (C_H₂O) and electrolyte-free water clearance (eC_H₂O) to differentiate hypo-/hypernatremia. Classic: C_H₂O = V·(1 − U_osm/P_osm); positive = dilute urine excreting free water (diabetes insipidus, polydipsia, water-load recovery), negative = concentrated urine conserving free water (dehydration, SIADH). Electrolyte-free: eC_H₂O = V·(1 − (U_Na + U_K)/P_Na), which better predicts the direction of serum sodium change — a negative eC_H₂O means the urine is electrolyte-free-water-rich and tends to raise serum Na⁺, informing IV fluid choice. Optional Na/K inputs enable the electrolyte-free calculation. Derived from Rose, Shimizu 2002 (Nephron), and NephSIM. Point estimate; interpret with full clinical context. Not medical advice.

AI Tools

AI RAG Chunk Quality Scorer

Score candidate RAG chunk-splitting schemes for a document across four metrics — coherence (clean sentence/paragraph boundaries), coverage (topic focus / key-term concentration), context overlap health, and chunk-size consistency — then compare up to three schemes side by side and recommend the best. Pure offline heuristics, no model calls.

Math & Numbers

Duct Size Calculator (Flow Rate × Velocity)

Size a duct cross-section from the air flow rate Q and the design mean velocity v: area A = Q/v. Circular duct diameter D = √(4A/π). Rectangular duct with aspect ratio r = a/b gives b = √(A/r) and a = r·b, plus the ASHRAE equivalent diameter D_eq = 1.30·(a·b)^0.625/(a+b)^0.25. Flow rate in m³/s/m³/h/CFM, velocity in m/s; dimensions reported in mm and inches.

Decimal places: 4

Outcome

Goodman n = 0.9091, Gerber n = 1.2500, and Soderberg n = 0.7407. Soderberg governs, and the point is outside the Goodman line.