Elysia Tools

Browse tools, examples, visual explainers, and topic guides from one clear workspace.

Top Categories

Hubs

Language
ZHDERUPTENFRES

Elysia Tools

Navigation

Tags

Heat Transfer Tools

Browse 7 online Heat Transfer tools for working with heat transfer data and operations in your browser.

Explore 7 Heat Transfer tools for working with heat transfer-related data and operations through a browser interface, with no software installation required.

Tools

7 matching tools

Tags

Related Tags

Tool usage guide

FAQ

What can I do with Heat Transfer tools?

You can use the available tools to work with heat transfer-related data and operations through your browser.

Do I need to install software?

No software installation is required. You can access the Heat Transfer tools through the browser interface.

How is my data handled?

Your browser submits operations for processing on Elysia Tools servers. Text inputs are not stored, and uploaded files are automatically deleted after 6 hours.

Home
Tools3212
Samples593
Visualizations471
Viewers103
Hubs239
Tags333
Images, Audio & Video657

Image, audio, and video processing, conversion, and optimization tools

Math, Date & Finance647

Calculators, numerics, date logic, statistics, and finance tools

Design & Color298

Color, layout, graphics, visual styling, and design helper tools

Text & Writing209

Writing, cleanup, formatting, extraction, and text analysis tools

Developer & Web193

Developer utilities, networking, web debugging, and automation helpers

Conversion & Encoding175

Format, file, archive, unit, and encoding conversion tools

Lead Generation Quiz Launch and Contact Handoff
Memorial Drafts: Family Review and Print Handoff
Private Habit Records: Backup, Restore and Sharing Review
Article to X and LinkedIn Drafts: Fact Review and Handoff
Markdown Interactive Deck Review and Offline Handoff

© 2026 Elysia Tools. All rights reserved.

DocsPricingAboutTerms of ServicePrivacy PolicyCookiesContact

Math & Numbers

Cylinder Radial Heat Conduction (Q=2πkL·ΔT/ln(r₂/r₁))

Compute radial steady-state heat conduction through a single-layer cylindrical wall (Fourier's law in cylindrical coordinates): radial heat flow rate Q = 2π·k·L·ΔT/ln(r₂/r₁) (W), inner-surface heat flux q_inner = Q/(2π·r₁·L) (W/m²), outer-surface heat flux q_outer = Q/(2π·r₂·L) (W/m²), and cylindrical thermal resistance R = ln(r₂/r₁)/(2π·k·L) (K/W). k is the thermal conductivity (W/(m·K)); L the cylinder length; r₁ the inner radius, r₂ the outer radius (must have r₂ > r₁ > 0); ΔT the temperature difference (K; a °C difference equals a K difference, a °F difference is converted by ×5/9). ΔT may be negative (indicating reverse heat flow), but k, L, r₁ and r₂ must be positive. Length and radius in m/cm/mm.

Math & Numbers

Heat Conduction Calculator (Fourier's Law, q=kΔT/d)

Compute 1-D steady-state heat conduction through a flat slab (Fourier's law): heat flux q = k·ΔT/d (W/m²), heat flow rate Q = k·A·ΔT/d (W), and thermal resistance R = d/(k·A) (K/W). k is the thermal conductivity (W/(m·K)); ΔT is the temperature difference (K; a °C difference equals a K difference, a °F difference is converted by ×5/9); d the slab thickness; A the cross-section area. ΔT may be negative (indicating reverse heat flow), but k, d and A must be positive. Thickness in m/cm/mm, area in m²/cm².

Math & Numbers

Heat Convection Calculator (Newton's Law, q=hΔT)

Compute convective heat transfer (Newton's law of cooling): heat flux q = h·ΔT (W/m²), heat flow rate Q = h·A·ΔT (W), and convective thermal resistance R_conv = 1/(h·A) (K/W). h is the convective heat-transfer coefficient (W/(m²·K)); ΔT is the temperature difference between the surface and the fluid (K; a °C difference equals a K difference, a °F difference is converted by ×5/9); A the heat-transfer area. ΔT may be negative (indicating reverse heat flow), but h and A must be positive. Area in m²/cm².

Math & Numbers

Heat Exchanger LMTD Calculator (Log Mean Temperature Difference)

Compute the Log Mean Temperature Difference (LMTD) of a heat exchanger for parallel or counter flow. Parallel flow: ΔT₁ = T_h,in - T_c,in and ΔT₂ = T_h,out - T_c,out; counter flow: ΔT₁ = T_h,in - T_c,out and ΔT₂ = T_h,out - T_c,in. LMTD = (ΔT₁ - ΔT₂)/ln(ΔT₁/ΔT₂), or ΔT₁ when ΔT₁ = ΔT₂. A non-positive terminal difference (temperature cross) is physically impossible and is rejected. Optionally, with the overall heat transfer coefficient U (W/(m²·K)) and the heat transfer area A (m²), the heat transfer rate Q = U·A·LMTD (W) is returned. Temperatures are used only as differences: Δ°C = ΔK and Δ°F ×5/9 = ΔK; the LMTD is reported in K.

Math & Numbers

Heat Exchanger ε-NTU Calculator (Effectiveness-NTU Method)

Compute the effectiveness (ε) of a heat exchanger by the ε-NTU method. C*=C_min/C_max (0..1), NTU=U·A/C_min, q_max=C_min·(T_h,in-T_c,in), and ε=q_actual/q_max. Supports four arrangements: Parallel flow ε=[1-exp(-NTU(1+C*))]/(1+C*); Counter flow ε=[1-exp(-NTU(1-C*))]/[1-C*·exp(-NTU(1-C*))], or NTU/(1+NTU) when C*=1; Shell-and-tube 1-2 ε=2/[1+C*+√(1+C*²)·(1+exp(-NTU√(1+C*²)))/(1-exp(-NTU√(1+C*²)))]; Crossflow (both unmixed) ε=1-exp{(NTU^0.22/C*)·[exp(-C*·NTU^0.78)-1]}. When C*=0 (phase change on one side, boiler/condenser) every arrangement gives ε=1-exp(-NTU). Optionally supply T_h,in and T_c,in to recover the actual heat-transfer rate q=ε·q_max and both outlet temperatures. Temperatures are used only as differences: Δ°C=ΔK and Δ°F×5/9=ΔK.

Math & Numbers

Heat Radiation Calculator (Stefan-Boltzmann Law, Q=εσA·T⁴)

Compute thermal radiation from a blackbody/grey body (Stefan-Boltzmann law): blackbody emissive power E_b = σ·T⁴ (W/m²), total radiated power Q_rad = ε·σ·A·T⁴ (W); with an optional surrounding temperature T₀ it also computes the net radiative exchange Q_net = ε·σ·A·(T⁴-T₀⁴) (W). σ = 5.670374419e-8 W/(m²·K⁴); ε is the emissivity (0 < ε ≤ 1, blackbody ε=1); T is the ABSOLUTE temperature (K) — °C and °F are first converted to K (this is an absolute temperature, not a difference); A is the radiating area. Area in m²/cm².

Math & Numbers

Overall Heat Transfer Coefficient (1/U=ΣR)

Compute the overall heat transfer coefficient for series thermal resistances (flat-wall model): total resistance R_total = Σ R_i (K/W), thermal conductance G = 1/R_total (W/K), area-based coefficient U = 1/(R_total·A) (W/(m²·K)), and if a temperature difference is given the heat flow rate Q = ΔT/R_total (W). Each R_i is a layer resistance already containing the area factor (e.g. convection R_conv=1/(h·A), conduction R_cond=d/(k·A), fouling R_foul=R_f''/A). Enter one resistance (K/W) per line, at least one, all positive. ΔT may be negative (reverse heat flow); a °C difference equals a K difference, a °F difference is converted by ×5/9.

Math

502 tools

Browse 502 online math tools for working with math operations, data, and files in your browser. Text inputs are not stored, and uploaded files are deleted after 6 hours.

Area

50 tools

Browse 50 area-related tools in your browser. Processing runs on Elysia Tools servers; text inputs are not stored and uploaded files are deleted after 6 hours.

Heat Flow Rate

4 tools

Browse 4 online Heat Flow Rate tools for working with heat flow rate data in your browser. Text inputs are not stored, and uploaded files are deleted after 6 hours.

Length

59 tools

Browse 59 online length tools for working with length-related data and formats. Use them in your browser; text inputs are not stored and uploaded files are deleted after 6 hours.

Power

36 tools

Browse 36 online Power tools for working with power-related formats and operations in your browser. Text inputs are not stored, and uploaded files are deleted after 6 hours.