Elysia Tools

Browse tools, examples, visual explainers, and topic guides from one clear workspace.

Top Categories

Hubs

Language
ZHDERUPTENFRES

Elysia Tools

Navigation

Health

Breath Coherent Resonance / Wim Hof / Tummo / Box / 4-7-8 Coach with Capnometer-Style EtCO2 Estimation

· Last updated:2026-09-12

This tool is for informational purposes only and does not constitute medical, financial, or legal advice; consult a qualified professional for advice.

Plan six evidence-based breathing protocols — Wim Hof (30 breaths + retention + recovery), coherent/resonance ~5.5 bpm at the 0.1 Hz RSA peak, 4-7-8, box 4-4-4-4, Tummo-style and Buteyko reduced breathing — with a per-second timeline, capnometer-style EtCO2 trajectory model, parasympathetic/sympathetic phase marking, CP/BOLT reference and contraindication warnings.

Details

What this tool helps you do

Six protocols with per-second timelines and a coarse EtCO2 estimation model. Wim Hof follows the official four steps (30 deep breaths → exhale ~90% and retain → 15 s recovery breath, 3-4 rounds). Coherent breathing targets ~5.5 bpm where heart rate and breath synchronize at 0.1 Hz (respiratory sinus arrhythmia peak, Steffen 2017). 4-7-8 (Weil), box 4-4-4-4, Tummo-style vase rounds and Buteyko reduced breathing with control-pause checks are also modelled. EtCO2 dynamics: breathing phases relax toward the alveolar-air-equation steady state PA = 0.863·VCO2/VA with a ~60 s body-store time constant (clamped 17-46 mmHg); breath-holds rise ~3.5 mmHg/min; baseline 40 mmHg. This is a teaching estimate, not a medical capnometer. Contraindications (breath-hold/hyperventilation work): pregnancy, epilepsy, uncontrolled hypertension, cardiovascular disease, panic disorder, recent surgery — consult a physician; never practise in or near water (shallow-water blackout).

Execution

Run this tool

Fill in the form, run the tool, and review the result in one place.

Samples

Examples that match this tool

Related

Continue with connected tools and hubs

Written by the Elysia Tools team

Tool usage guide

Learn when to use this tool, what it supports, and how real users apply it.

Key facts

Category
Health
Input types
select, number
Output type
html
Sample coverage
4
API ready
Yes

Overview

The Breath Coherent Resonance & Wim Hof Coach models structured breathing sessions with second-by-second pacing and mathematical end-tidal CO2 (EtCO2) estimation. It supports six evidence-informed protocols—Coherent 0.1 Hz, Wim Hof, 4-7-8, Box 4-4-4-4, Tummo-style, and Buteyko reduced breathing—to help you visualize autonomic nervous system shifts, retention intervals, and projected respiratory dynamics.

When to use

  • Structuring multi-round Wim Hof or Tummo breathing sessions with accurate pacing, retention timers, and recovery holds.
  • Designing resonance frequency and heart rate variability (HRV) training sessions targeting the 0.1 Hz RSA peak (~5.5 bpm).
  • Simulating respiratory gas exchange dynamics and estimated EtCO2 trajectories during breath-hold or slow-breathing exercises.

How it works

  1. 1Select a breathing protocol and adjust parameters like rounds, breath cadence, retention duration, or target breaths per minute.
  2. 2The engine generates a per-second timeline, tagging each interval with its dominant autonomic state (sympathetic vs. parasympathetic).
  3. 3An alveolar gas equation model projects EtCO2 levels based on minute ventilation, body-store relaxation constants, and retention accumulation rates.

Use cases

  • HRV biofeedback practitioners pacing slow-paced 5.5 bpm coherent breathing protocols.
  • Breathwork practitioners planning multi-phase Wim Hof cycles with calculated retention windows.
  • Health and wellness coaches benchmarking client progress against Control Pause (CP) and BOLT references.

Examples

1. 3-Round Wim Hof Session Planning

Breathwork Instructor

Background

An instructor wants to demonstrate how hyperventilation rounds and subsequent holds impact projected alveolar CO2 levels across a group class.

Problem

Needs an accurate timeline with clear sympathetic and parasympathetic phase indications and safe pacing guidelines.

How to use

Select 'Wim Hof' as the protocol, configure 3 rounds, set breath pacing to 2.4 seconds, retention to 75 seconds, and recovery hold to 15 seconds.

protocol: wim-hof, rounds: 3, breathsPerRound: 30, breathCycleSec: 2.4, retentionSec: 75, recoveryHoldSec: 15, baselineEtco2: 40

Outcome

Generates an 8:06 minute visual session timeline showing EtCO2 dropping from 40 mmHg to ~19.7 mmHg before rebounding during breath-holds.

2. Coherent Resonance HRV Pacing

Wellness Coach

Background

A coach needs a 10-minute resonance breathing exercise to support parasympathetic tone and optimize heart rate variability.

Problem

Requires precise 0.1 Hz (5.5 bpm) pacing parameters without inducing hyperventilation or CO2 washout.

How to use

FAQ

Is the EtCO2 readout a substitute for clinical capnography?

No, it is a mathematical teaching estimate using alveolar gas approximations, not real-time medical sensor data.

What is the 0.1 Hz peak in coherent breathing?

It is the frequency (~5.5 to 6 breaths per minute) where heart rate oscillations and breathing synchronize for maximal respiratory sinus arrhythmia.

How does the tool estimate EtCO2 during breath retention?

It models linear carbon dioxide accumulation in the lungs at a standard resting metabolic rate of approximately 3.5 mmHg per minute.

What safety precautions apply to hyperventilation and breath-hold protocols?

Never practice in or near water, while driving, or while standing, due to the risk of fainting and shallow-water blackout.

Who should avoid high-intensity retention or hyperventilation protocols?

People who are pregnant, have epilepsy, cardiovascular disease, uncontrolled hypertension, or panic disorder should avoid these methods without medical clearance.

Home
Tools3212
Samples593
Visualizations471
Viewers103
Hubs239
Tags333
Images, Audio & Video657

Image, audio, and video processing, conversion, and optimization tools

Math, Date & Finance647

Calculators, numerics, date logic, statistics, and finance tools

Design & Color298

Color, layout, graphics, visual styling, and design helper tools

Text & Writing209

Writing, cleanup, formatting, extraction, and text analysis tools

Developer & Web193

Developer utilities, networking, web debugging, and automation helpers

Conversion & Encoding175

Format, file, archive, unit, and encoding conversion tools

Lead Generation Quiz Launch and Contact Handoff
Memorial Drafts: Family Review and Print Handoff
Private Habit Records: Backup, Restore and Sharing Review
Article to X and LinkedIn Drafts: Fact Review and Handoff
Markdown Interactive Deck Review and Offline Handoff

© 2026 Elysia Tools. All rights reserved.

DocsPricingAboutTerms of ServicePrivacy PolicyCookiesContact
Media

Copyright-Free FLAC Audio Samples

Lossless FLAC audio samples for testing and development, mirrored from MP3 set with nature sounds and meditation music

Media

Copyright-Free WAV Audio Samples

Uncompressed PCM WAV audio samples for testing and development, mirrored from MP3 set with nature sounds and meditation music

Java

Android Image Processing Java Samples

Android Java image processing examples including reading/saving images, scaling, and format conversion

Kotlin

Android Image Processing Kotlin Samples

Android Kotlin image processing examples including reading/saving images, scaling, and format conversion

Health

Intermittent Fasting Planner

Plan a 16:8, 18:6, 20:4, OMAD or custom fast: enter your last meal time and get a color-coded 24-hour timeline plus hour-by-hour milestones (metabolic switch, fat-burning, ketosis, autophagy) as concrete clock times.

Health

Carbon Footprint Calculator (Activity-Based)

Annual personal CO₂e from diet, energy, fuels, flights, transit, and waste with per-category breakdown and target comparisons.

Health

Drug Half-Life Concentration Calculator

Estimate plasma drug concentration at a chosen time after an IV bolus using a one-compartment model with first-order elimination: C(t) = (Dose / Vd) · e^(-k·t), where k = ln2 / t½. Includes initial concentration C0, elimination rate constant k, percent remaining, and number of half-lives elapsed. Valid only for linear pharmacokinetics — NOT for Michaelis-Menten drugs (phenytoin, high-dose ethanol) or multi-compartment distribution. Reference: theophylline Vd ≈ 0.45 L/kg, t½ ≈ 8 h. Not medical advice.

Health

Logistic Population Growth (N_t = K/(1+((K−N₀)/N₀)·e^(−rt)))

Compute Verhulst logistic growth toward carrying capacity K, with instantaneous dN/dt and capacity percentage.

Select 'Coherent / resonance 0.1 Hz', set duration to 10 minutes, and ensure the target rate is set to 5.5 breaths per minute.

protocol: coherent, minutes: 10, coherentBpm: 5.5, baselineEtco2: 40

Outcome

Outputs a stable 10:00 minute timeline keeping estimated EtCO2 in the 40–41 mmHg range with continuous parasympathetic phase marking.