Heat Exchanger LMTD Calculator (Log Mean Temperature Difference)

· Last updated:2026-07-22

Compute the Log Mean Temperature Difference (LMTD) of a heat exchanger for parallel or counter flow. Parallel flow: ΔT₁ = T_h,in - T_c,in and ΔT₂ = T_h,out - T_c,out; counter flow: ΔT₁ = T_h,in - T_c,out and ΔT₂ = T_h,out - T_c,in. LMTD = (ΔT₁ - ΔT₂)/ln(ΔT₁/ΔT₂), or ΔT₁ when ΔT₁ = ΔT₂. A non-positive terminal difference (temperature cross) is physically impossible and is rejected. Optionally, with the overall heat transfer coefficient U (W/(m²·K)) and the heat transfer area A (m²), the heat transfer rate Q = U·A·LMTD (W) is returned. Temperatures are used only as differences: Δ°C = ΔK and Δ°F ×5/9 = ΔK; the LMTD is reported in K.

Execution

Run this tool

Fill in the form, run the tool, and review the result in one place.

Samples

Examples that match this tool

Related

Continue with connected tools and hubs

Written by the Elysia Tools team
Math502
Area50
Heat Transfer7

Tool usage guide

Learn when to use this tool, what it supports, and how real users apply it.

Key facts

Category
Math & Numbers
Input types
select, number
Output type
json
Sample coverage
4
API ready
Yes

Overview

Calculate the log mean temperature difference (LMTD) for parallel-flow or counter-flow heat exchangers using four stream temperatures. The calculator reports LMTD in K and can also calculate heat transfer rate when overall heat transfer coefficient U and area A are provided.

When to use

  • Estimate the effective temperature driving force in a heat exchanger.
  • Compare LMTD for parallel-flow and counter-flow arrangements.
  • Calculate heat transfer rate from U, A, and LMTD during thermal design.

How it works

  1. 1Enter the hot-stream inlet and outlet temperatures and the cold-stream inlet and outlet temperatures.
  2. 2Select parallel flow or counter flow and choose K, °C, or °F as the input temperature unit.
  3. 3The calculator determines the two terminal temperature differences and applies the LMTD formula.
  4. 4Optionally enter U in W/(m²·K) and A in m² to calculate Q = U·A·LMTD in watts.

Use cases

  • Thermal design of shell-and-tube and other heat exchangers.
  • Preliminary sizing checks using an overall heat transfer coefficient and heat transfer area.
  • Engineering review of inlet and outlet temperature measurements for counter-flow or parallel-flow equipment.

Examples

1. Counter-flow LMTD calculation

Thermal engineer

Background

An engineer is checking the temperature driving force for a counter-flow heat exchanger with known stream inlet and outlet temperatures.

Problem

Find the two terminal temperature differences and the resulting LMTD.

How to use

Select Counter Flow, enter hot-stream temperatures of 100 °C and 60 °C, and cold-stream temperatures of 20 °C and 50 °C.

flowType: counter; hotInletTemp: 100; hotOutletTemp: 60; coldInletTemp: 20; coldOutletTemp: 50; tempUnit: °C; decimalPlaces: 4

Outcome

The terminal differences are 50 K and 40 K, producing an LMTD of approximately 44.8142 K.

2. Parallel-flow heat transfer rate

Process design engineer

Background

A process designer wants to estimate the heat transfer rate for a parallel-flow exchanger using its overall coefficient and area.

Problem

Calculate both LMTD and Q from the stream temperatures, U, and A.

How to use

Select Parallel Flow, enter hot-stream temperatures of 120 °C and 70 °C, cold-stream temperatures of 30 °C and 60 °C, U of 500 W/(m²·K), and A of 2 m².

FAQ

What does the LMTD calculator calculate?

It calculates the log mean temperature difference of a heat exchanger for parallel-flow or counter-flow operation.

What temperature inputs are required?

You need the hot-stream inlet and outlet temperatures and the cold-stream inlet and outlet temperatures.

What units does the calculator use for LMTD?

The result is reported in kelvin (K). Temperature differences in °C equal differences in K, while Fahrenheit differences are converted to K.

Can it calculate heat transfer rate?

Yes. Enter both U and A to calculate Q = U·A·LMTD in watts.

What happens if a terminal temperature difference is zero or negative?

The calculator rejects the input because a non-positive terminal difference indicates a physically impossible temperature cross.

Hub

HVAC Load, Airflow, Refrigeration, and Thermal Comfort Review

Estimate HVAC loads, airflow, psychrometric states, refrigeration conditions, heat-transfer effects, and thermal comfort for an engineering review.

Home
Tools3212
Samples593
Visualizations471
Viewers103
Hubs239
Tags333
Images, Audio & Video657

Image, audio, and video processing, conversion, and optimization tools

Math, Date & Finance647

Calculators, numerics, date logic, statistics, and finance tools

Design & Color298

Color, layout, graphics, visual styling, and design helper tools

Text & Writing209

Writing, cleanup, formatting, extraction, and text analysis tools

Developer & Web193

Developer utilities, networking, web debugging, and automation helpers

Conversion & Encoding175

Format, file, archive, unit, and encoding conversion tools

Lead Generation Quiz Launch and Contact Handoff
Memorial Drafts: Family Review and Print Handoff
Private Habit Records: Backup, Restore and Sharing Review
Article to X and LinkedIn Drafts: Fact Review and Handoff
Markdown Interactive Deck Review and Offline Handoff

© 2026 Elysia Tools. All rights reserved.

DocsPricingAboutTerms of ServicePrivacy PolicyCookiesContact
DevOps

ELK Stack Log Analysis Samples

Comprehensive ELK Stack (Elasticsearch, Logstash, Kibana) samples for log aggregation, processing, and visualization in distributed systems

Log Processing

Nginx Log Parser Samples

Comprehensive Nginx log samples for testing log-parser tool, including access logs and error logs with various formats and scenarios

Security

Log Files with Sensitive Data

Sample log files containing various types of PII (Personally Identifiable Information) for testing PII detection and log redaction tools

Log Analysis

Splunk Log Analysis Samples

Comprehensive Splunk configuration and query examples for log analysis, monitoring, and operational intelligence

Math & Numbers

Average Calculator

Compare arithmetic, geometric, and harmonic averages for a numeric dataset in one place

Math & Numbers

Cam Follower Displacement Calculator

Calculate the follower displacement, velocity coefficient, acceleration coefficient and pressure angle during the cam rise phase. Supports constant-velocity, constant-acceleration, harmonic (SHM) and cycloidal motion laws.

Math & Numbers

Confidence Interval Calculator

Calculate confidence intervals for a sample mean or proportion using either raw data or summary statistics

Math & Numbers

Geometric Mean Calculator

Calculate the geometric mean of positive numeric values for growth rates, ratios, and multiplicative datasets

flowType: parallel; hotInletTemp: 120; hotOutletTemp: 70; coldInletTemp: 30; coldOutletTemp: 60; tempUnit: °C; heatTransferCoeff: 500; area: 2; decimalPlaces: 4

Outcome

The terminal differences are 90 K and 10 K, the LMTD is approximately 36.4096 K, and the calculated heat transfer rate is approximately 36,409.5691 W.