Elysia Tools

Browse tools, examples, visual explainers, and topic guides from one clear workspace.

Top Categories

Hubs

Idioma
ZHDERUPTENFRES

Elysia Tools

Navegação

Math & Numbers

Heat Exchanger ε-NTU Calculator (Effectiveness-NTU Method)

· Última atualização:2026-07-24

Compute the effectiveness (ε) of a heat exchanger by the ε-NTU method. C*=C_min/C_max (0..1), NTU=U·A/C_min, q_max=C_min·(T_h,in-T_c,in), and ε=q_actual/q_max. Supports four arrangements: Parallel flow ε=[1-exp(-NTU(1+C*))]/(1+C*); Counter flow ε=[1-exp(-NTU(1-C*))]/[1-C*·exp(-NTU(1-C*))], or NTU/(1+NTU) when C*=1; Shell-and-tube 1-2 ε=2/[1+C*+√(1+C*²)·(1+exp(-NTU√(1+C*²)))/(1-exp(-NTU√(1+C*²)))]; Crossflow (both unmixed) ε=1-exp{(NTU^0.22/C*)·[exp(-C*·NTU^0.78)-1]}. When C*=0 (phase change on one side, boiler/condenser) every arrangement gives ε=1-exp(-NTU). Optionally supply T_h,in and T_c,in to recover the actual heat-transfer rate q=ε·q_max and both outlet temperatures. Temperatures are used only as differences: Δ°C=ΔK and Δ°F×5/9=ΔK.

Execução

Executar esta ferramenta

Preencha o formulário, execute a ferramenta e veja o resultado no mesmo lugar.

Exemplos

Exemplos compatíveis com esta ferramenta

Relacionado

Continue com ferramentas e temas relacionados

Escrito pela equipe Elysia Tools
Math502
Heat Transfer7

Tool usage guide

Veja quando usar esta ferramenta, o que ela suporta e como os usuários a aplicam.

Key facts

Categoria
Math & Numbers
Tipos de entrada
select, number
Tipo de saída
json
Cobertura de exemplos
4
API pronta
Sim

Overview

Calculate heat exchanger effectiveness with the ε-NTU method for parallel-flow, counter-flow, shell-and-tube 1-2, or crossflow arrangements. Enter both heat-capacity rates, the overall heat transfer coefficient, and heat transfer area to obtain C*, NTU, and ε; optionally add inlet temperatures to calculate heat-transfer rate and outlet temperatures.

When to use

  • Estimate heat exchanger effectiveness when inlet and outlet temperatures are not yet known.
  • Compare parallel-flow, counter-flow, shell-and-tube 1-2, and crossflow arrangements using the same operating data.
  • Calculate actual heat transfer and both outlet temperatures when hot- and cold-side inlet temperatures are available.

How it works

  1. 1Enter the hot-side capacity rate C_h, cold-side capacity rate C_c, overall coefficient U, and heat transfer area A.
  2. 2Select the exchanger arrangement; the calculator determines C_min, C_max, C*=C_min/C_max, and NTU=U·A/C_min.
  3. 3The appropriate ε-NTU relation is applied to calculate heat exchanger effectiveness.
  4. 4Optionally provide both inlet temperatures to calculate q_max, actual heat transfer q, and the hot- and cold-side outlet temperatures.

Use cases

  • Thermal design checks for process, HVAC, and energy systems.
  • Early comparison of heat exchanger flow arrangements.
  • Estimating heat duty and outlet temperatures from capacity rates and inlet conditions.

Examples

1. Counter-flow effectiveness estimate

Thermal design engineer

Background

An engineer is checking the effectiveness of a counter-flow heat exchanger before completing a detailed thermal design.

Problem

Determine C*, NTU, and effectiveness from the capacity rates, overall coefficient, and heat transfer area.

How to use

Select Counter Flow and enter C_h=1000 W/K, C_c=1500 W/K, U=500 W/(m²·K), and A=10 m².

{"exchangerType":"counter","hotCapacityRate":1000,"coldCapacityRate":1500,"overallU":500,"area":10,"tempUnit":"°C","decimalPlaces":4}

Outcome

The calculator returns C_min=1000 W/K, C_max=1500 W/K, C*=0.6667, NTU=5, and effectiveness ε≈0.928. Without inlet temperatures, heat-transfer rate and outlet temperatures are not calculated.

2. Crossflow heat duty and outlet temperatures

Heat exchanger analyst

Background

An analyst has equal hot- and cold-side capacity rates and measured inlet temperatures for an unmixed crossflow exchanger.

FAQ

What inputs are required?

Enter C_h, C_c, U, and A. The exchanger type is selectable, with counter flow used by default.

Which exchanger arrangements are supported?

The calculator supports parallel flow, counter flow, shell-and-tube 1-2, and crossflow with both fluids unmixed.

What does NTU mean?

NTU is the number of transfer units, calculated as U·A/C_min.

Are inlet temperatures required?

No. They are optional. Provide both inlet temperatures to calculate actual heat transfer and outlet temperatures.

Which temperature units can I use?

Use Kelvin, Celsius, or Fahrenheit. The calculation uses temperature differences, with Δ°C=ΔK and Δ°F×5/9=ΔK.

Hub

HVAC Load, Airflow, Refrigeration, and Thermal Comfort Review

Estimate HVAC loads, airflow, psychrometric states, refrigeration conditions, heat-transfer effects, and thermal comfort for an engineering review.

Home
Tools3212
Samples593
Visualizations471
Viewers103
Hubs239
Tags333
Images, Audio & Video657

Image, audio, and video processing, conversion, and optimization tools

Math, Date & Finance647

Calculators, numerics, date logic, statistics, and finance tools

Design & Color298

Color, layout, graphics, visual styling, and design helper tools

Text & Writing209

Writing, cleanup, formatting, extraction, and text analysis tools

Developer & Web193

Developer utilities, networking, web debugging, and automation helpers

Conversion & Encoding175

Format, file, archive, unit, and encoding conversion tools

Lead Generation Quiz Launch and Contact Handoff
Memorial Drafts: Family Review and Print Handoff
Private Habit Records: Backup, Restore and Sharing Review
Article to X and LinkedIn Drafts: Fact Review and Handoff
Markdown Interactive Deck Review and Offline Handoff

© 2026 Elysia Tools. All rights reserved.

DocsPricingAboutTerms of ServicePrivacy PolicyCookiesContact
Python

Web Image Processing Python Samples

Web Python image processing examples using PIL/Pillow including reading, saving, resizing, and format conversion

Java

Android Image Processing Java Samples

Android Java image processing examples including reading/saving images, scaling, and format conversion

Kotlin

Android Image Processing Kotlin Samples

Android Kotlin image processing examples including reading/saving images, scaling, and format conversion

Rust

Web Image Processing Rust Samples

Web Rust image processing examples including image read/save, scaling, and format conversion

Math & Numbers

Absolute Value Calculator

Calculate the absolute value of positive, negative, or decimal numbers and explain the sign relationship

Math & Numbers

Air Changes per Hour (ACH, n = Q/V)

Compute the air change rate (ACH / n) of a room from the outdoor supply airflow Q and the room volume V: n = Q/V (1/h). Three modes: solve ACH (given Q and V), solve airflow (given n and V), or solve volume (given n and Q). Flow in m³/s/m³/h/CFM, volume in m³/ft³/L. Also reports the well-mixed single-zone purge time to reach a target residual fraction ε (default 1%): t = −ln(ε)/n hours.

Math & Numbers

Bearing Life L10 Calculator

Calculate the basic rating life of a rolling bearing: L10 = (C/P)^p, with p = 3 for ball bearings and p = 10/3 for roller bearings. When a speed is provided, converts to L10h in operating hours.

Math & Numbers

Bolt Torque Clamp Force Calculator

Convert between bolt tightening torque and axial clamp force. T = K·F·d, where K is the nut factor (~0.20 for dry steel). Solve torque from force, or force from torque.

Problem

Calculate effectiveness, actual heat transfer, and both outlet temperatures.

How to use

Select Crossflow unmixed and enter C_h=2000 W/K, C_c=2000 W/K, U=400 W/(m²·K), A=8 m², T_h,in=120 °C, and T_c,in=30 °C.

{"exchangerType":"crossflow","hotCapacityRate":2000,"coldCapacityRate":2000,"overallU":400,"area":8,"hotInletTemp":120,"coldInletTemp":30,"tempUnit":"°C","decimalPlaces":4}

Outcome

The calculator returns NTU=1.6, ε=0.5713, q_max=180000 W, actual heat transfer of about 102829.4725 W, T_h,out≈68.5853 °C, and T_c,out≈81.4147 °C.