Elysia Tools

Browse tools, examples, visual explainers, and topic guides from one clear workspace.

Top Categories

Hubs

Language
ZHDERUPTENFRES

Elysia Tools

Navigation

Media

ATSC A/85 Broadcast Loudness Validator

· Last updated:2026-10-07

Validate audio against ATSC A/85 (CALM Act): -24 LKFS ± 2 LU program loudness per ITU-R BS.1770-4, -2.0 dBTP oversampled true peak, 48 kHz delivery check and a dialnorm cross-check, with a per-file short-term timeline chart.

Details

What this tool helps you do

ATSC A/85 is the recommended practice behind US loudness law: the CALM Act made its target binding for US broadcast television as of December 13, 2012, and the FCC enforces it. The anchor number is -24 LKFS (LUFS) with a ± 2 LU tolerance, so the pass window runs from -26 to -22 LKFS, measured over the full program with the ITU-R BS.1770-4 K-weighted, gated method — A/85 measures the whole program, not a dialogue-gated subset. Commercials, promos and programs are held to the same target, which is exactly what the CALM Act polices: ad breaks stop jumping out. The maximum true peak is -2.0 dBTP, oversampled; broadcast chains add transmitter limiting and re-encodes after delivery, so many engineers limit masters at -2.3 dBTP to stay safely inside. ATSC DTV audio is 48 kHz (AC-3/E-AC-3), so non-48 kHz files are flagged. Dialnorm is the metadata field that tells consumer decoders how loud the program is; this tool cross-checks the dialnorm you plan to encode against the measured loudness (recommended value: the measurement rounded to a whole dB) — when they disagree, playback normalisation is wrong even though the audio measured clean. A short-term (3 s) timeline chart shows whether loud moments stay proportionate. Measurement uses FFmpeg's ebur128 filter; files are only read, never modified.

Execution

Run this tool

Fill in the form, run the tool, and review the result in one place.

Samples

Examples that match this tool

Related

Continue with connected tools and hubs

Written by the Elysia Tools team

Tool usage guide

Learn when to use this tool, what it supports, and how real users apply it.

Key facts

Category
Media
Input types
file, select, number
Output type
html
Sample coverage
4
API ready
Yes

Overview

The ATSC A/85 Broadcast Loudness Validator evaluates audio files against North American television broadcast standards and CALM Act requirements. It measures integrated program loudness per ITU-R BS.1770-4 (-24 LKFS ± 2 LU), inspects oversampled true peak levels (-2.0 dBTP ceiling), verifies standard 48 kHz sampling rates, and cross-checks intended AC-3 dialnorm metadata against measured loudness with a 3-second short-term timeline chart.

When to use

  • Before delivering commercials, promos, or syndicated program masters to US television networks and local broadcast affiliates.
  • When auditing audio deliverables to ensure compliance with FCC CALM Act loudness regulations.
  • When verifying that planned Dolby Digital (AC-3/E-AC-3) dialnorm metadata values match measured program loudness.

How it works

  1. 1Upload individual audio files or a ZIP archive, select the content type (program, commercial, or promo), and enter your planned dialnorm metadata value.
  2. 2The validator scans the audio using ITU-R BS.1770-4 gating to measure integrated loudness (LKFS), maximum true peak (dBTP), sample rate (kHz), and short-term loudness dynamics over time.
  3. 3Review the interactive HTML report featuring compliance pass/fail badges, dialnorm alignment checks, sample rate confirmation, and a short-term loudness timeline chart.

Use cases

  • Validating 30-second commercial spot masters to prevent loudness penalties or rejections under the CALM Act.
  • Verifying long-form television program delivery packages for syndication and network transmission.
  • Cross-referencing dialnorm metadata settings against full-mix audio tracks before authoring Dolby Digital bitstreams.

Examples

1. Commercial Spot CALM Act Compliance Check

Broadcast Audio Engineer

Background

A post-production facility is delivering a 30-second commercial master intended for national cable and broadcast distribution.

Problem

The engineer needs to confirm the ad will not trigger CALM Act violations by exceeding the -24 LKFS target or breaching the -2.0 dBTP peak ceiling.

How to use

Upload the final WAV mix file, set Content type to 'Commercial (CALM Act scope)', and leave Expected dialnorm at -24 dB.

Content type: commercial, Expected dialnorm: -24 dB

Outcome

The validator generates a report confirming an integrated loudness of -24.0 LKFS and a max true peak of -2.5 dBTP with a full pass status.

2. Long-Form Program Dialnorm Alignment Verification

QC Operator

Background

A network ingest operator is quality-checking a 60-minute episodic television master before AC-3 encoding.

Problem

Audio mixed slightly off-target can cause improper decoder normalization if the authoring dialnorm does not match the actual mix level.

How to use

FAQ

What is the acceptable ATSC A/85 loudness target for US broadcast?

ATSC A/85 targets -24 LKFS with an allowable tolerance of ±2 LU, creating an acceptable compliance window of -26.0 LKFS to -22.0 LKFS measured across the entire duration.

What is the maximum allowed true peak level under ATSC A/85?

The maximum permitted true peak level is -2.0 dBTP measured with oversampling to prevent inter-sample clipping during downstream transmission encoding.

Why is 48 kHz sample rate verification required?

ATSC digital television standards specify 48 kHz audio for AC-3 and E-AC-3 broadcast delivery, so non-48 kHz files are flagged as non-compliant.

What is the dialnorm cross-check and why does it matter?

Dialnorm is metadata informing consumer decoders of program loudness. If the entered dialnorm value diverges from the measured loudness, playback volume will be improperly scaled on consumer devices.

Are uploaded audio files modified during the validation process?

No. Files are read strictly in non-destructive mode for measurement and analysis; no audio data is re-encoded or altered.

Home
Tools3212
Samples593
Visualizations471
Viewers103
Hubs239
Tags333
Images, Audio & Video657

Image, audio, and video processing, conversion, and optimization tools

Math, Date & Finance647

Calculators, numerics, date logic, statistics, and finance tools

Design & Color298

Color, layout, graphics, visual styling, and design helper tools

Text & Writing209

Writing, cleanup, formatting, extraction, and text analysis tools

Developer & Web193

Developer utilities, networking, web debugging, and automation helpers

Conversion & Encoding175

Format, file, archive, unit, and encoding conversion tools

Lead Generation Quiz Launch and Contact Handoff
Memorial Drafts: Family Review and Print Handoff
Private Habit Records: Backup, Restore and Sharing Review
Article to X and LinkedIn Drafts: Fact Review and Handoff
Markdown Interactive Deck Review and Offline Handoff

© 2026 Elysia Tools. All rights reserved.

DocsPricingAboutTerms of ServicePrivacy PolicyCookiesContact
Media

Copyright-Free FLAC Audio Samples

Lossless FLAC audio samples for testing and development, mirrored from MP3 set with nature sounds and meditation music

Media

Copyright-Free MP3 Audio Samples

Collection of royalty-free audio samples for testing and development purposes including nature sounds, meditation music, and ambient audio

Media

Copyright-Free WAV Audio Samples

Uncompressed PCM WAV audio samples for testing and development, mirrored from MP3 set with nature sounds and meditation music

Media

Copyright-Free Raw PCM Audio Samples

Raw PCM s16le audio samples featuring nature ambience and relaxing music for waveform, playback, and conversion workflows

Media

EBU R128 Broadcast Loudness Validator

Validate audio against EBU R128: integrated programme loudness at -23.0 LUFS with EBU Mode gating, oversampled true peak at -1.0 dBTP, loudness range (Tech 3342) and momentary / short-term maxima, with a per-file timeline chart.

Media

CALM Act Commercial Loudness Checker

Check whether a commercial is louder than the programme it accompanies, per the FCC CALM Act rules and ATSC A/85: compare average loudness, grade the excess on the A/85 listener comfort scale, and flag loud-opening “gaming” with momentary-loudness diagnostics.

Media

Audio CD Red Book Checker

Check album tracks against the Red Book CD-DA standard: 44.1 kHz / 16-bit / stereo PCM, sample peaks, 4-second minimum tracks, 99-track limit, and disc capacity in sectors.

Media

Audio Gapless Album Validator

Validate an album for gapless playback: inter-track seam gaps, pre-roll and tail silence, encoder delay metadata, and sample-format consistency across every track.

Upload the program stereo audio master, select 'Program (long-form)', and input the intended dialnorm tag (-24 dB).

Content type: program, Expected dialnorm: -24 dB

Outcome

The report highlights that the file measures -21.2 LKFS, flags a dialnorm mismatch warning, and recommends setting dialnorm to -21 dB or remastering the mix.