Elysia Tools

Browse tools, examples, visual explainers, and topic guides from one clear workspace.

Top Categories

Hubs

Language
ZHDERUPTENFRES

Elysia Tools

Navigation

Media

EBU R128 Broadcast Loudness Validator

· Last updated:2026-10-07

Validate audio against EBU R128: integrated programme loudness at -23.0 LUFS with EBU Mode gating, oversampled true peak at -1.0 dBTP, loudness range (Tech 3342) and momentary / short-term maxima, with a per-file timeline chart.

Details

What this tool helps you do

EBU R128 (v5.0) normalises programmes to an average loudness of -23.0 LUFS. This validator measures each file the way an EBU-Mode meter does: ITU-R BS.1770-4 K-weighted blocks with the two-stage gate (an absolute gate at -70 LUFS discards silence, then a relative gate 10 LU below the ungated level discards quiet passages), so long pauses no longer drag the reading down. Produced programmes must land within ± 0.5 LU of target; a wider ± 1.0 LU is the informative tolerance for live broadcasts. The Maximum True Peak limit is -1.0 dBTP, measured oversampled — a sample-peak meter can read -1.0 dBFS while inter-sample peaks sit above the limit. Loudness range (LRA, EBU Tech 3342: the span between the 10th and 95th percentiles of gated 3-second blocks) is reported as a descriptor: R128 itself sets no limit, individual broadcasters bolt their own on top. The R128 s1 short-form profile (ads, promos, trailers) keeps the same loudness target and true-peak limit but does not apply the LRA descriptor. Momentary (400 ms) and short-term (3 s) maxima plus a short-term timeline chart show whether the programme lives inside the target band or only averages there. FFmpeg's ebur128 filter performs the measurement; files are only read, never modified.

Execution

Run this tool

Fill in the form, run the tool, and review the result in one place.

Samples

Examples that match this tool

Related

Continue with connected tools and hubs

Written by the Elysia Tools team

Tool usage guide

Learn when to use this tool, what it supports, and how real users apply it.

Key facts

Category
Media
Input types
file, select
Output type
html
Sample coverage
4
API ready
Yes

Overview

The EBU R128 Broadcast Loudness Validator analyzes audio files against European broadcast standards, measuring integrated loudness at -23.0 LUFS with two-stage EBU Mode gating, oversampled true peak levels up to -1.0 dBTP, and Loudness Range (LRA). It delivers immediate compliance assessments and short-term loudness timeline charts to verify delivery readiness without altering the source audio.

When to use

  • Before submitting broadcast masters to European television networks or streaming platforms requiring EBU R128 compliance.
  • When checking commercials, promos, or trailers against the R128 s1 short-form profile limits.
  • During quality control to diagnose inter-sample peaks or excessive dynamic swings across programme timelines.

How it works

  1. 1Upload standalone audio files or a ZIP bundle and choose the appropriate target profile (produced programme, live broadcast, or short-form).
  2. 2The validator processes the audio using ITU-R BS.1770-4 K-weighting with absolute (-70 LUFS) and relative (-10 LU) gating to calculate integrated loudness.
  3. 3It computes oversampled Maximum True Peak (dBTP), Loudness Range (Tech 3342), and momentary / short-term maxima, rendering a visual compliance report and timeline graph.

Use cases

  • Broadcaster delivery validation to catch true-peak overshoots and integrated loudness deviations on television episodes.
  • Commercial and trailer QC to ensure advertising masters adhere to R128 s1 specifications.
  • Post-production dynamic range audits using Loudness Range (LRA) and short-term timeline charts to balance dialogue and effects.

Examples

1. Validating a Stereo TV Programme Master

Broadcast Post-Production Engineer

Background

A documentary audio mix needs final QC before delivery to a European broadcaster with strict -23.0 LUFS delivery requirements.

Problem

Verify that dialogue-heavy sequences and quiet scenes meet the ±0.5 LU integrated tolerance and stay beneath the -1.0 dBTP ceiling.

How to use

Upload the 48 kHz WAV master file and select the 'Programme, produced (± 0.5 LU)' profile to run the analysis.

Validation profile: r128-program

Outcome

The report confirms an integrated loudness of -23.0 LUFS (0.0 LU deviation), true peak at -2.4 dBTP, and displays an LRA descriptor alongside an in-tolerance timeline graph.

2. Auditing a Commercial Spot Under R128 s1

Commercial Audio Mixer

Background

An advertising agency is preparing a 30-second promo intended for multi-channel broadcast distribution.

Problem

Ensure high-energy sound design does not exceed the true-peak ceiling while hitting the integrated target without triggering LRA-related rejection flags.

How to use

FAQ

What are the pass/fail criteria for standard produced programmes under EBU R128?

A produced programme passes when its integrated loudness measures -23.0 LUFS within a ±0.5 LU tolerance and its Maximum True Peak remains at or below -1.0 dBTP.

How does EBU Mode gating handle silent passages or long pauses?

It applies a two-stage gate: an absolute gate at -70 LUFS discards silence, followed by a relative gate 10 LU below the ungated level to prevent low-level passages from skewing the integrated measurement.

Why is oversampled true peak measurement necessary instead of sample peak?

Sample-peak meters only read discrete digital samples, missing inter-sample peaks generated during digital-to-analog conversion that can exceed -1.0 dBTP and cause distortion.

What is the difference between the standard profile and the R128 s1 profile?

The standard profile enforces target tolerances and tracks Loudness Range (LRA), whereas the R128 s1 profile is tailored for short-form content like ads and trailers where LRA is not evaluated.

Does this tool modify or normalize my original audio files?

No. The validator only inspects audio streams to produce diagnostic metrics and compliance reports; source files are never altered.

Home
Tools3212
Samples593
Visualizations471
Viewers103
Hubs239
Tags333
Images, Audio & Video657

Image, audio, and video processing, conversion, and optimization tools

Math, Date & Finance647

Calculators, numerics, date logic, statistics, and finance tools

Design & Color298

Color, layout, graphics, visual styling, and design helper tools

Text & Writing209

Writing, cleanup, formatting, extraction, and text analysis tools

Developer & Web193

Developer utilities, networking, web debugging, and automation helpers

Conversion & Encoding175

Format, file, archive, unit, and encoding conversion tools

Lead Generation Quiz Launch and Contact Handoff
Memorial Drafts: Family Review and Print Handoff
Private Habit Records: Backup, Restore and Sharing Review
Article to X and LinkedIn Drafts: Fact Review and Handoff
Markdown Interactive Deck Review and Offline Handoff

© 2026 Elysia Tools. All rights reserved.

DocsPricingAboutTerms of ServicePrivacy PolicyCookiesContact
Media

Copyright-Free FLAC Audio Samples

Lossless FLAC audio samples for testing and development, mirrored from MP3 set with nature sounds and meditation music

Media

Copyright-Free MP3 Audio Samples

Collection of royalty-free audio samples for testing and development purposes including nature sounds, meditation music, and ambient audio

Media

Copyright-Free WAV Audio Samples

Uncompressed PCM WAV audio samples for testing and development, mirrored from MP3 set with nature sounds and meditation music

Media

Copyright-Free Raw PCM Audio Samples

Raw PCM s16le audio samples featuring nature ambience and relaxing music for waveform, playback, and conversion workflows

Media

ATSC A/85 Broadcast Loudness Validator

Validate audio against ATSC A/85 (CALM Act): -24 LKFS ± 2 LU program loudness per ITU-R BS.1770-4, -2.0 dBTP oversampled true peak, 48 kHz delivery check and a dialnorm cross-check, with a per-file short-term timeline chart.

Media

CALM Act Commercial Loudness Checker

Check whether a commercial is louder than the programme it accompanies, per the FCC CALM Act rules and ATSC A/85: compare average loudness, grade the excess on the A/85 listener comfort scale, and flag loud-opening “gaming” with momentary-loudness diagnostics.

Media

Audio Gapless Album Validator

Validate an album for gapless playback: inter-track seam gaps, pre-roll and tail silence, encoder delay metadata, and sample-format consistency across every track.

Media

Normalization History Card

Generate a shareable before/after report card for any loudness change: gain applied, LUFS, true peak, sample peak, loudness range, waveforms and third-octave spectral deltas.

Upload the final mix WAV file, choose the 'Short-form, ads and promos (R128 s1)' validation profile, and review the summary report.

Validation profile: r128-s1

Outcome

Generates a clean compliance badge showing -23.1 LUFS integrated loudness, -1.2 dBTP true peak, and suppresses short-form LRA evaluation.